Industrial Electrical Solutions  ·  Designed for Performance
Power Quality

APFC Panels
Automatic Power Factor Correction

Automatically maintain power factor close to unity under fluctuating loads. Reduce KVA demand charges, lower distribution losses and avoid utility penalties with multi-stage capacitor switching and optional detuned reactors.

Vertex APFC Panel

kVAR Range

Custom multi-stage

Switching

Contactor / Thyristor

Control

Microprocessor based

Target PF

Up to 0.99 lag

Maintain High Power Factor Automatically

APFC panels sense reactive power demand and switch capacitor banks in stages to keep power factor at the desired setpoint, reducing losses and demand charges.

Intelligent Controller

Microprocessor-based APFC relay with programmable stages, VAR sensing and protection against over/under voltage and harmonics.

Contactor or Thyristor

Capacitor-duty contactors for standard applications or thyristor switching for rapid response and reduced inrush in sensitive systems.

Detuned Reactors

Optional series reactors (typically 5.67% or 7%) to detune the system and protect capacitors from harmonic resonance.

Heavy-Duty Capacitors

MPP / APP duty-filled capacitors rated for continuous operation under industrial voltage and temperature conditions.

Multi-Stage Design

4, 6, 8, 12 or more stages sized to match load pattern for fine control and minimal hunting.

Complete Documentation

GA drawings, single-line, stage settings, test reports and O&M manuals supplied with every panel.

Technical Specifications

Typical configuration. Final kVAR and stage count determined from load study.

Parameter Specification
Rated Voltage415 V AC, 3-phase, 50 Hz
kVAR RatingAs per load study (multi-stage)
Number of Stages4 / 6 / 8 / 12 or custom
Switching TypeContactor-based or Thyristor-based
ControllerMicroprocessor-based APFC relay
Capacitor TypeHeavy-duty MPP / APP
DetuningOptional series reactors (5.67% / 7%)
IncomerMCCB / ACB as required
Degree of ProtectionIP42 / IP54
Target Power FactorTypically 0.95 – 0.99 lag

Where APFC Delivers Value

Any installation with inductive loads and fluctuating reactive demand benefits from automatic correction.

01

Industrial Plants

Motors, transformers and inductive process loads.

02

Commercial Buildings

HVAC, elevators and large lighting loads.

03

Data Centres

UPS and cooling systems with variable load profiles.

04

Hospitals & Institutions

Continuous power quality and demand optimisation.

05

Water Utilities

Pumping stations with cyclic motor operation.

06

Manufacturing

Any facility facing power factor penalties.

Related Products

Complementary solutions

Ready to improve your power factor?

Share your load profile, existing PF data or energy bills. We will size and propose the right APFC solution.

Request a Quote