The main LT switchboard of the plant. Receives power from transformers or DG sets and distributes it safely to MCCs, distribution boards, large loads and utility feeders. Designed for high fault levels and continuous industrial duty.
Current Rating
Up to 6300 A
Fault Level
50 – 80 kA / 1 s
Form of Separation
Form 2b – 4b
Standards
IEC 61439-1/2
PCC panels sit at the top of the low-voltage hierarchy. Their busbar design, short-circuit withstand and form of separation determine the safety and uptime of the entire plant.
Electrolytic copper or aluminium busbars sized by temperature-rise design verification. Heat-shrink insulated with SMC/DMC supports.
Air Circuit Breakers for incomers up to 6300 A with microprocessor releases. MCCB/ACB outgoing feeders for MCCs and large loads.
Internal separation options up to Form 4b for maximum safety during maintenance and to limit fault propagation.
Multifunction meters, numerical relays, earth leakage protection, under-voltage and reverse power protection as required.
Optional bus coupler with interlocks and auto-changeover / synchronising logic between transformers and DG sets.
GA drawings, SLD, BOM, routine test reports and O&M manuals supplied with every panel.
Typical ratings. Final parameters are confirmed against project SLD and site fault study.
| Parameter | Specification |
|---|---|
| Rated Operational Voltage | 415 V AC, 3-phase 4-wire, 50 Hz (690 V optional) |
| Rated Insulation Voltage | 690 V / 1000 V |
| Main Busbar Rating | 100 A – 6300 A |
| Short-Time Withstand Current | 50 / 65 / 80 kA for 1 s |
| Form of Internal Separation | Form 1, 2b, 3b, 4a or 4b |
| Degree of Protection | IP42 / IP54 indoor · IP55 / IP65 outdoor |
| Incomer | ACB with microprocessor release up to 6300 A |
| Outgoing Feeders | MCCB / ACB / SFU as required |
| Busbar Material | Electrolytic copper or aluminium |
| Enclosure | 2.0 mm CRCA frame, 1.6 mm doors, powder coated |
| Reference Standards | IEC 61439-1 & IEC 61439-2 (IS/IEC 61439) |
| Communication | Modbus RTU / TCP for SCADA & energy management |
PCC panels are the primary power distribution point in almost every industrial and commercial facility.
Chemical, pharma, food & beverage, cement and steel plants.
Automotive, textile, engineering and discrete manufacturing units.
Airports, metros, hospitals, data centres and large commercial complexes.
Water treatment plants, pumping stations and municipal facilities.
DG synchronisation and changeover systems for continuous power.
Solar and hybrid plants requiring robust LT distribution.
Complementary solutions
Share your SLD, transformer ratings, fault level and feeder list. Our team will prepare a complete technical proposal.